0 Cookie Img

Cold Acid Unit

Cold Acid Unit
Cold Acid Unit
Product Code : JHTD-CHY-LS Series
Product Description

Cold Acid Unit that we are offering is engineered to be used in varied laboratories for determining and testing quality of varied kind of cold acids. Moreover, the temperature of acid can also be cooled down with the use of such system. This is equipped with graded cool compressor, high capacity acid tank, heat insulation, heat exchanger and other contact parts & components to ensure longer hassle-free functioning. It has absolutely anti-corrosive design, as coated with premium quality coating material. In addition to this, Cold Acid Unit has intelligent temperature control system to ensure stable running and convenient operation.

The Main Technical Parameters :

For battery formation process, battery must be injected with low temperature acid which generally be controlled at 5 oC ~ 10 oC or even lower. It is necessary to cool down acid solution to ensure the quality of batteries.

JHTD-CHY-LS series acid chiller is designed for supporting the battery production line. With a cooling speed, low power consumption, small size, small footprint, simple integrated control and other advantages.

Introduce :

  • JHTD-CHY-LS series acid chiller is consist of refrigerating units, heat exchangers, acid incubator, security protection devices, and control panel. The re-circulation system has been improved by integrated refrigeration systems and storage integration. The system has a small size, light weight, small installation space advantages. Acid components can be adjusted according to user requirements on size, installation (vertical, horizontal).
  • Refrigeration components selected US. and Japanese import famous brand compressor, built-in security protection, low noise, energy saving and durable.
  • Cooling circulating pump imported products, high flow, high efficiency, long-lasting durability.
  • Using low-noise axial fan, to ensure smooth quiet running unit.
  • Equipped with imported precision digital display temperature controller can accurately control the temperature + 1oC ,the design temperature range 5 oC -40 oC.
  • Thick stainless steel water tank evaporator, built-in devices such as automatic replenishment, cleaning and easy maintenance
  • The use of highly efficient shell and tube heat exchangers and corrugated fins series inner grooved copper tube for air-cooled heat exchanger, excellent performance, reliable operation.
  • The refrigeration system using refrigerant is R22 refrigerant, reducing environmental pollution.
  • Heat exchange components of heat exchange tube is made of graphite modified polypropylene plastic, with good corrosion resistance to acid alkali and organic solvents , high heat exchange efficiency in 100 oC.

Principle of refrigeration :

JHTD-CHY-LS series acid chiller is consisting by refrigeration unit, heat ex-changers group, and acid storage containers. Refrigeration unit is mainly by closed compressor, condenser, solenoid valves, filter drier, evaporator, gas-liquid separator, protection devices and other components.

Operating Principal :

When refrigeration, low-temperature refrigerant inside the evaporator sucked into the cylinder, compressed through the compressor. Making high-temperature high-pressure gas into the air (or water) heat ex-changer, the high temperature and pressure of the refrigerant gas and cooling medium for heat exchange, the heat pass on to the air (or water), and refrigerant gas condenses to high-pressure liquid. High-pressure liquid throttled by expansion valve into low temperature low pressure liquid entering the evaporator. In the low-pressure liquid refrigerant within the evaporator vaporized, absorption surrounding medium (coolant water) heat, so that coolant water cooled as required and via the pump to the chiller equipment, low temperature refrigerant after evaporation is sucked and compressed by compressor, so that cycle of continuous system to make cold water. Cold water through the heat exchange unit exchange heat with acid, in order to achieve cooling acid.

Technical Parameters :

JHTD-CHY-is series cold acid unit

Model

UNIT

JHTD-CHY-LS-0.5

Refrigerating unit


15 HP

Cooling(ambient temperature 35oC)
Water inlet 12oC
Water outlet 7oC

KW

44

103 kcal/h

38

Power Supply

V/ph/Hz

380/3/50

Compressor type


Scroll Type

Compressor Power

KW

11.9

Pump Power

KW

1.5

Flow rate

M3/h

7.6

Evaporator

type

Water tank type / shell and tube type

Tank volume

L

270

Size of connecting pipe

DN

50

Withstand voltage

Bar

26

Condenser


fin

Refrigerant


R22 / R407c

Charge amount

Kg

13.0

Throtting way


Expansion value

Protector


High Pressure, overload, antifreeze, delayed, overheat

Noise

Db(A)

66

Heat exchange


10

Conveying acid pump power

KW

0.75

Conveying acid pump (max)

L/min

350

Diluted acid incubator

M3

1

Refrigerating unit weight

kg

465

Acid chiller dimension

LxWxH

2590x1800x1980

Cold acid ability from 40oC to 10oC Ambient temperature 25oC

M3/H

0.5

Incubator Cooling efficiency

Temperature rising <0.5oC/h

Contact Us

101, Bldg No 20, Songshan Road, Nangang District, Economic High Tech Development Zone, Hyderabad, Telangana, 500039, India